Knowledge sharing
How to choose between two options of centrifugal fan exhaust/supply in the cabinet
The same centrifugal fan is installed at the bottom of the cabinet to blow in, and installed at the top of the cabinet to draw out. The parts are exactly the same, but the heat dissipation effect, cleanliness in the cabinet, and fan life may differ a lot. Many cabinets on site did not have proper heat dissipation solutions, not because the fan was chosen too small, but because the wind was flowing in the wrong direction, or because it was not clear whether the cabinet should have positive or negative pressure.
Cabinet air conditioning autumn and winter parameter setting tutorial: cooling start, heating hysteresis, dehumidification threshold analysis
After entering autumn, the temperature difference between day and night widens, and the air humidity fluctuates violently. Outdoor energy storage cabinets, PLC control cabinets, communication cabinets, wind turbine pitch cabinets, and stacker mechanical and electrical cabinets are most likely to encounter a hidden fault: equipment heats up during the day, and the temperature inside the cabinets rises; At night, the environment rapidly cools down, and the water vapor inside the cabinet condenses, forming condensation that corrodes the circuit board, reduces insulation, and causes short circuits, flashover, and signal false alarms. Many operation and maintenance personnel mistakenly believe that the weather is cool in autumn and winter, and directly turn off the cabinet air conditioning, which is a typical misconception.
Misconception about heat dissipation in electrical cabinets: Ventilation fans ≠ dehumidification, the more they blow, the more humid they become
The first reaction of many equipment maintenance personnel is: it's too hot in the cabinet, add a fan to blow it out; It's too damp in the cabinet, please add a fan to blow it out. It seems that "ventilation" can solve both heat dissipation and dehumidification problems at the same time.But physically, these two things take completely different paths. The cooling fan deals with "temperature", which is essentially heat. It uses forced convection to take away hot air and replenish relatively cold air. It transports air and does not change the moisture content in the air; And dehumidifiers deal with "humidity", which is essentially water vapor. By condensing and precipitating water or absorbing moisture with desiccants, they directly "extract" the water vapor from the air and reduce the moisture content. One only focuses on reducing the temperature and the other only focuses on reducing the humidity. The objects, principles, and effects of the two treatments are completely different.
How to read the lifespan and MTBF of a fan? 6 key points for long-term stable operation of industrial fans
The MTBF on the fan nameplate, which can last for hundreds of thousands of hours, is not about "how long it can last", it measures random reliability; The L10 (B10) lifespan is truly close to the on-site lifespan - the number of operating hours when 10% of a batch of fans fail due to bearing/grease wear. To ensure the long-term stable operation of industrial fans, remember an iron rule: for every 10-15 ℃ increase in temperature above the rated benchmark, the service life of the lubricating grease is approximately halved. In addition, selecting the right bearings, cleaning the filter screen frequently, and actively replacing it according to 80% of the service life are much more cost-effective than repairing it afterwards.
How to choose filter fans for port stacker crane control cabinets with dust and high humidity
When it comes to cooling the electrical control cabinet, many people's first reaction is to "install a filtering fan". Under the dual pressure of dust and high humidity, this simple idea often collapses: the larger the air volume, the easier it is for the cabinet to be filled with dust and moisture; If a filter is installed, should the contactor oxidize or not. What really needs to be clarified first is the logic of selection, not just the quantity of air flow.
Cabinet air conditioning vs filter fan: why the fan cannot withstand high temperature conditions
When choosing a temperature control solution for a cabinet, many engineers are torn between a filter fan and a cabinet air conditioner: the fan is cheap, the air conditioner is expensive, which one should they choose? Most people don't know that this is not a matter of 'which is better', but rather a matter of 'which condition determines which one can be used'.The filter fan and cabinet air conditioner are not a substitute relationship, but a working condition adaptation relationship. The filtering fan relies on "ventilation and cooling", which can only bring the temperature inside the cabinet close to the ambient temperature. Once the environment is high, it will fail; Cabinet air conditioning relies on the "refrigeration cycle" to keep the temperature inside the cabinet below the ambient temperature, and can only truly withstand high temperature conditions. The judgment criteria are simple: the heat generated inside the cabinet plus the ambient temperature determines whether you can use a fan.
How to Tell If the Refrigerant Is Leaking? Can You Just Add Refrigerant to an Industrial Cabinet AC?
Should the thermostat be normally open or normally closed? Electrician Selection Formula
Friends who work in electrical control cabinets, cabinet air conditioners, or dehumidification systems have almost always been asked the same question: should the thermostat be normally open (NO) or normally closed (NC)?
What is the difference between intelligent thermostat and ordinary mechanical thermostat
Temperature control is the fundamental guarantee for the stable operation of electrical cabinets, energy storage compartments, outdoor box transformers, and wind power control cabinets. Many projects are torn between choosing a traditional mechanical thermostat or an intelligent thermostat with RS485 communication for temperature control during the planning phase? Many people simply believe that the difference between the two is only in accuracy, but in fact, from control principles, operating logic to operation and maintenance methods, the two belong to completely different control schemes, with huge differences in applicable scenarios, risk points, and long-term usage costs.
How to choose salt spray protection and IP rating for EC wind turbines in coastal energy storage projects?
The coastal area is the "geomantic treasure land" of energy storage projects, but also the "testing ground" of electronic equipment: high salt fog, high humidity, typhoon rainstorm, and the air is full of "invisible corrosives". EC fans, as the main source of heat dissipation for energy storage cabinets, are often the first target of salt spray attacks. Choosing the wrong one can result in minor issues such as abnormal noise and decreased efficiency, while in severe cases, bearings may lock up, condensation may cause short circuits, and the entire cabinet may shut down. So how to do salt spray protection and how to choose the IP level.